6K TRANSFORMER / POWER SUPPLY
$49.95
- UL Listed
- UL 2161 Ground Fault Protection
- Self-adjusting: Range 2kv-6kv, 30ma
- Overload Circuit Protection
- High power factor
- Low electromagnetic disturbance
- Reduced energy consumption
- Dimensions: 2.5″ W x 1.8″ H x 6.9″ L
- Indoor Use Only
- Warranty: One Year
FOOTAGE CHART
Diameter (mm) | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 15 |
---|---|---|---|---|---|---|---|---|
Gas Pressure (mmHg) | 18 | 17 | 15 | 13 | 12 | 11 | 10 | 9 |
Load legnth in feet (Red Neon) |
7 | 8 | 9 | 11 | 13 | 16 | 17 | 19 |
Load legnth in feet (Argon) |
8 | 9 | 11 | 12 | 15 | 18 | 20 | 23 |
Note: Deduct one foot for each pair of electrodes from above figures
Ship to USA (not including HI & AK) $8.95
10K TRANSFORMER / POWER SUPPLY
$53.95
- UL Listed
- UL 2161 Ground Fault Protection
- Self-adjusting: Range 3kv-10kv, 30ma
- Overload Circuit Protection
- High power factor
- Low electromagnetic disturbance
- Reduced energy consumption
- Dimensions: 2.5″ W x 1.8″ H x 6.9″ L
- Indoor Use Only
- Warranty: One Year
FOOTAGE CHART
Diameter (mm) | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 15 |
---|---|---|---|---|---|---|---|---|
Gas Pressure (mmHg) | 18 | 17 | 15 | 13 | 12 | 11 | 10 | 9 |
Load legnth in feet (Red Neon) |
16 | 18 | 21 | 25 | 28 | 31 | 34 | 39 |
Load legnth in feet (Argon) |
18 | 21 | 25 | 30 | 33 | 37 | 40 | 48 |
Note: Deduct one foot for each pair of electrodes from above figures
Ship to USA (not including HI & AK) $8.95
12 K TRANSFORMER / POWER SUPPLY
$64.95
- UL Listed
- UL 2161 Ground Fault Protection
- Self-adjusting: Range 9kv-12kv, 30ma
- Overload Circuit Protection
- High power factor
- Low electromagnetic disturbance
- Reduced energy consumption
- Dimensions: 2.625″ W x 1.75″ H x 9.625″ L
- Indoor Use Only
- Warranty: One Year
FOOTAGE CHART
Diameter (mm) | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 15 |
---|---|---|---|---|---|---|---|---|
Gas Pressure (mmHg) | 18 | 17 | 15 | 13 | 12 | 11 | 10 | 9 |
Load legnth in feet (Red Neon) |
22 | 27 | 29 | 31 | 32 | 33 | 34 | 39 |
Load legnth in feet (Argon) |
18 | 21 | 25 | 30 | 33 | 42 | 45 | 51 |
Note: Deduct one foot for each pair of electrodes from above figures
Ship to USA (not including HI & AK) $8.95
12 K CONVENTIONAL MAGNETIC NEON TRANSFORMER
$179.95
- UL Listed
- UL 2161 Ground Fault Protection
- Resin Fill Construction for Long Life
- 12,000kv, 30ma
- Auto Reset
- Heavy Duty Hanger Bracket
- Dimensions: 4.25″Wx 5.25″Hx 10.5″L
- Weight: 24 lbs.
- Indoor Use Only
- Warranty: One Year
FOOTAGE CHART
Diameter (mm) | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 15 |
---|---|---|---|---|---|---|---|---|
Gas Pressure (mmHg) | 18 | 17 | 15 | 13 | 12 | 11 | 10 | 9 |
Load legnth in feet (Red Neon) |
16 | 18 | 26 | 29 | 32 | 35 | 39 | 45 |
Load legnth in feet (Argon) |
24 | 27 | 31 | 35 | 38 | 42 | 46 | 55 |
Note: Deduct one foot for each pair of electrodes from above figures
Ship to USA (not including HI & AK) $8.95
15 K CONVENTIONAL MAGNETIC NEON TRANSFORMER
$189.95
- UL Listed
- UL 2161 Ground Fault Protection
- Resin Fill Construction for Long Life
- 15,000kv, 30ma
- Auto Reset
- Heavy Duty Hanger Bracket
- Dimensions: 4.25″Wx 5.25″Hx 10.5″L
- Weight: 24 lbs.
- Indoor Use Only
- Warranty: One Year
FOOTAGE CHART
Diameter (mm) | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 15 |
---|---|---|---|---|---|---|---|---|
Gas Pressure (mmHg) | 18 | 17 | 15 | 13 | 12 | 11 | 10 | 9 |
Load legnth in feet (Red Neon) |
16 | 18 | 32 | 36 | 40 | 45 | 50 | 60 |
Load legnth in feet (Argon) |
18 | 21 | 25 | 30 | 33 | 37 | 40 | 48 |
Note: Deduct one foot for each pair of electrodes from above figures
Ship to USA (not including HI & AK) $8.95